Home >Products >FGS Rubber Rotor Pump >Mechanical seal

Mechanical seal

Item No: HLS-AB001

Details
The built-in wear-resistant lining plate in the pump cavity can effectively protect the pump cavity from wear, prolong the service life of the pump and reduce the later use cost. It can be maintained
Message
Introduction

Description

Features

Parameters

Product features:

The built-in wear-resistant lining plate in the pump cavity can effectively protect the pump cavity from wear, prolong the service life of the pump and reduce the later use cost. It can be maintained online, and the parts can be checked or replaced by opening the pump cover. There is no need to lift the equipment and remove the pump from the pipeline. It is convenient for maintenance and saves a lot of maintenance time. The spiral rotor runs smoothly with stable pressure and flow. Compact structure, small floor area, easy to install and transport pipeline routing. It can realize the mixed transportation of gas, liquid and solid. Such as massive materials, fibers, hair, etc., will not block. The pump can rotate forward and backward, the inlet and outlet can be interchanged, and the two functions of loading and unloading can be realized at the same time. It can transport medium with viscosity ≤ 2 million CP. It has strong self-priming ability, and the suction range can reach 8.5 meters. Independent seal cavity design, keep the seal face lubrication, idle for 15 minutes will not produce any damage to the pump. The rotor and pump body can be made of corresponding materials according to different conveying conditions.

 

 

Helsh-Tech


Application fields:

Environmental protection: municipal sewage, chemical wastewater, lime slurry, precipitated sludge, thickened sludge, etc.

Petrochemical Industry: heavy oil, heavy oil, source oil, fuel oil, lubricating oil, asphalt, sludge, oil, catalyst, multicomponent oil, etc.

Papermaking: polyacrylic size, sizing solution, rosin size, paper, coating, amine emulsion, defoamer, filter aid, water treatment chemicals, etc.

Food: dairy products, fruit juice, puree, concentrated juice, cream, syrup, chocolate, ice cream, condensed milk, condiment, distiller's grains, soybean protein, mushroom powder, etc.

Daily chemical products: AES, MES, AOS, Las, K12, glycerin, fatty alcohol, detergent, facial cleanser, shower gel, shampoo, toothpaste, soap, detergent slurry, etc.

Fine chemicals: dyes, pigments, sodium, adhesives, silicone oil, leather oil, emulsion explosives, etc.

Chemical fiber: glass fiber, viscose paste, PVA, vinylon size, refined fiber size, spandex size, polymer chip, man-made fiber, etc.

Pharmaceutical: ointment, extract, medicine emulsion, pill paste, medicament and so on. Coating: paint, paint, ink, resin, additives, organic solvents, etc.

Fire fighting: foam pump and fire pump.

 

 

Helsh-Tech

As a wholesale manufacturer of double rotor pump, the application of rotor pump immediately endangers the service life of rotor pump. So do you have to pay attention to any problems when mastering the application of rotor pump? First of all, before you run, we have to check whether the oil in the gearbox is sufficient, and the lubricating oil should be removed and replaced on time. The general removal and replacement time is about 4000 hours. Before operation, the water gate at the inlet and outlet of the pipeline should be opened. When the material enters, we need to be good at rotating the rotor pump to ensure that everything is normal before the operation can be declared, and the operation can not be carried out under the condition of empty pump. There is also something that we must pay attention to during the whole operation process of the rotor pump. In the case of operation, we should pay attention to the output power of the motor and its operation condition. If there is any abnormality, we need to stop running to search for the cause. With the rotary seal of the diesel engine rotor pump shell, can allow each minute one to three drops, if exceed should compress ring. There should be no leakage and scalding of the machine seal.

Mainly Product

Designed for Low-to-High Viscosity Media

General Appearance Cam Lobe Pump

The General Appearance Cam Lobe Pump is the most popular choice among users. This type of pump is mainly configured with a horizontal left-right inlet and outlet direction. The commonly used connectio

More+

Top Inlet and Outlet Cam Lobe Pump

The Top Inlet and Outlet Cam Lobe Pump is specifically designed for special inlet and outlet piping arrangements. When there is material in the pipeline, this pump has excellent self-priming capabilit

More+

HEP1 Homogenizing Emulsifying Pump

The pump cavity of hep1 homogeneous emulsion pump is equipped with a set of double stator and double rotor. The internal stress of rotor stator and cavity source materials can be eliminated by forging

More+

Enlarged Inlet Model - Cam Lobe Pump

The inlet of the enlarged inlet cam lobe pump is specially processed to effectively expand the feeding area. Coupled with two-lobed arcuate or butterfly-shaped rotors, it can better transpor

More+

Right-angle Gear Reducer Model - Cam Lobe Pump

The main feature of the right-angle gear reducer cam lobe pump is its short horizontal axial installation space, which meets the special requirements for installation space in certain applications. Ad

More+

Seal cooling & pressure system - cam lobe pump

The cam lobe pump with a mechanical seal circulation cooling and pressure maintaining system is primarily used in applications with high requirements for pump sealing. The pump is equipped with a mech

More+

Mobile Hopper & VFD Cam Lobe Pump

The product is equipped with a thermal insulation device, which can heat the pump body through steam, hot water or hot oil to make the material flow better, prevent the material from solidifying in th

More+

HEP3 Homogenizing Emulsifying Pump

There are three groups of rotors and stators in the working cavity of HEp3 homogeneous emulsion pump. Each rotor has two layers of toothed discs. There are 12 layers of toothed discs in the three grou

More+

Working principle diagram

The pump cavity of hep1 homogeneous emulsion pump is equipped with a set of double stator and double rotor. The internal stress of rotor stator and cavity source materials can be eliminated by forging

More+

Working principle diagram

The pump cavity of hep1 homogeneous emulsion pump is equipped with a set of double stator and double rotor. The internal stress of rotor stator and cavity source materials can be eliminated by forging

More+

Messages